How to Fix Anycubic Error 10119: Y-Axis Homing Failed
Anycubic error 10119 (Y-Axis Homing Failed) appears on the Kobra 3, Kobra 3 Max, Kobra X, and Kobra S1 when the heated bed cannot reach the Y-axis home position during the startup homing sequence. The printer stops immediately to protect the frame and motion system from a crash.
What the Error Means
The Y axis drives the heated bed front-to-back. During homing the bed travels toward the home end-stop, and the firmware expects a signal confirming it has arrived. On the Kobra 3 Max, two Y-axis motors work in tandem to move the larger bed — a loose connector on either motor can prevent homing. On strain-gauge models like the Kobra S1, force detection replaces a physical end-stop switch, so debris under the bed or a faulty sensor are additional failure points. Error 10119 indicates the confirmation signal was never received within the allowed time.
Step-by-Step Fix
- Go to Move Axis on the touchscreen and jog the Y axis forward and backward to check that the bed responds to commands. If the bed does not move at all, the motor circuit is the primary suspect.
- Power off the printer. Inspect the Y-axis motor cable connector at the motor and at the mainboard. On Kobra 3 Max — which uses dual Y motors — check both motor connectors and reseat any that feel loose or partially inserted.
- Crouch down and look under the heated bed for any object, fallen screw, or filament wad that could prevent the bed from traveling its full stroke. Remove any obstruction.
- On strain-gauge models (Kobra S1): remove the printhead and clean the underside of the hotbed with a dry cloth to remove filament residue or dust that could cause a false force reading during homing.
- Re-run homing from the touchscreen and observe whether the bed moves freely all the way to the home position.
- If the bed still fails to home after clearing obstructions and reseating cables, the Y-axis stepper motor or the mainboard Y-axis driver may have failed. Replace the motor or contact Anycubic support for mainboard evaluation.
Parts Required
- Replacement Y-axis stepper motor (if motor is confirmed failed)
- On dual-motor models: spare Y-axis motor set (Kobra 3 Max)
If error 10119 recurs despite clear rails and secure cable connections, contact Anycubic support for further diagnosis.
Frequently asked questions
What does Anycubic 10119 mean?
Anycubic error 10119 (Y-Axis Homing Failed) appears on the Kobra 3, Kobra 3 Max, Kobra X, and Kobra S1 when the heated bed cannot reach the Y-axis home position during the startup homing sequence. The printer stops immediately to protect the frame and motion system from a crash.
How do I fix Anycubic 10119?
Anycubic error 10119 means the heated bed failed to reach the Y-axis home position. Fix loose motor cables, dual-motor issues, and strain-gauge faults on Kobra 3 and Kobra S1.